๐Ÿ” CVE Alert

CVE-2026-33390

HIGH 8.1

Incorrect privilege assignment for Arc sensors in Guardian/CMC before 26.2.0

CVSS Score
8.1
EPSS Score
0.0%
EPSS Percentile
0th

An Incorrect Privilege Assignment vulnerability was discovered in the synchronization functionality due to Arc sensors receiving CLI permissions. An authenticated user with limited privileges can push administrative CLI commands through the sync, altering the device configuration, and/or affecting its availability.

CWE CWE-266
Vendor nozomi networks
Product guardian
Published Jul 9, 2026
Last Updated Jul 9, 2026
Stay Ahead of the Next One

Get instant alerts for nozomi networks guardian

Be the first to know when new high vulnerabilities affecting nozomi networks guardian are published โ€” delivered to Slack, Telegram or Discord.

Get Free Alerts โ†’ Free ยท No credit card ยท 60 sec setup

CVSS v3 Breakdown

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
High
Availability
High

Affected Versions

Nozomi Networks / Guardian
0 < 26.2.0
Nozomi Networks / CMC
0 < 26.2.0

References

NVD โ†— CVE.org โ†— EPSS Data โ†—
security.nozominetworks.com: https://security.nozominetworks.com/NN-2026:13-01

Credits

This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.