CVE-2026-127122
Out-of-bounds write with too many MCR blocks in a Connect request
CVSS Score
0.0
EPSS Score
0.0%
EPSS Percentile
0th
P-Net before 1.0.4 does not check the number of MCR request blocks in a Connect request against the number of multicast communication relations that an Application Relationship has room for (PNET_MAX_MC_CR, 1 by default). Each further block is written past the end of the array, into the rest of the Application Relationship and, with more blocks, into the following one. The written data comes from the request. No established Application Relationship is needed, and the attacker requires ADJACENT network access. Builds with PNET_OPTION_MC_CR disabled are not affected.
| CWE | CWE-787 |
| Vendor | rt-labs |
| Product | p-net |
| Published | Nov 13, 2026 |
Stay Ahead of the Next One
Get instant alerts for rt-labs p-net
Be the first to know when new unknown vulnerabilities affecting rt-labs p-net are published โ delivered to Slack, Telegram or Discord.
Get Free Alerts โ
Free ยท No credit card ยท 60 sec setup
Affected Versions
RT-Labs / P-Net
0 < 1.0.4