CVE-2026-102700
gnttab: cache-flush handling may cause page reference leak
CVSS Score
0.0
EPSS Score
0.0%
EPSS Percentile
0th
With its original introduction, GNTTAB_cache_flush was made available uniformly. XSA-232 (CVE-2017-14318) then covered an omitted NULL pointer check, yet the addition of that check failed to adjust the subsequent error path. That error path fails to drop a page reference in case the specified page is owned by a special system domain (DOM_IO and DOM_COW are system domains which can have memory pages assigned to them.)
| Vendor | xen |
| Product | xen |
| Published | Oct 13, 2026 |
| Last Updated | Oct 13, 2026 |
Stay Ahead of the Next One
Get instant alerts for xen xen
Be the first to know when new unknown vulnerabilities affecting xen xen are published โ delivered to Slack, Telegram or Discord.
Get Free Alerts โ
Free ยท No credit card ยท 60 sec setup
Affected Versions
Xen / Xen
All versions affected References
Credits
This issue was discovered independently by Andrew Cooper of Citrix and