CVE-2026-101022
Grid Protection Alliance openPDC and openHistorian Server-Side Request Forgery (SSRF)
CVSS Score
4.3
EPSS Score
0.0%
EPSS Percentile
0th
A Modbus connection feature on openPDC accepts a caller-specified destination address and port with no restriction on which internal hosts may be targeted. An authenticated user can attempt connections to arbitrary internal network destinations, revealing which destinations are reachable. With repeated attempts, an attacker may be able to map the internal network.
| CWE | CWE-918 |
| Vendor | grid protection alliance |
| Product | openpdc |
| Published | Oct 9, 2026 |
Stay Ahead of the Next One
Get instant alerts for grid protection alliance openpdc
Be the first to know when new medium vulnerabilities affecting grid protection alliance openpdc are published โ delivered to Slack, Telegram or Discord.
Get Free Alerts โ
Free ยท No credit card ยท 60 sec setup
CVSS v3 Breakdown
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
None
Availability
None
Affected Versions
Grid Protection Alliance / openPDC
0 < 2.9.477 0 < 2.9.482
Grid Protection Alliance / openPDC (Docker image)
0 < 2.9.477 0 < 2.9.482
Grid Protection Alliance / openHistorian
0 < 2.8.580 0 < 2.8.585
References
Credits
Shubham Raj (Cipher) of Causal Security reported this vulnerability to CISA.