๐Ÿ” CVE Alert

CVE-2024-54017

MEDIUM 5.3
CVSS Score
5.3
EPSS Score
0.0%
EPSS Percentile
8th

A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V11.0), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SA82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SA82 (CP150) (All versions < V11.0), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SD82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SD82 (CP150) (All versions < V11.0), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SJ81 (CP100) (All versions >= V7.80), SIPROTEC 5 7SJ81 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SJ82 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SK82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SK82 (CP150) (All versions < V11.0), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SL82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SL82 (CP150) (All versions < V11.0), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7ST86 (CP300) (All versions < V11.0), SIPROTEC 5 7SX82 (CP150) (All versions < V11.0), SIPROTEC 5 7SX85 (CP300) (All versions < V11.0), SIPROTEC 5 7SY82 (CP150) (All versions < V11.0), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7UT82 (CP100) (All versions >= V7.80), SIPROTEC 5 7UT82 (CP150) (All versions < V11.0), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7VU85 (CP300) (All versions < V11.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V11.0). Affected devices do not use sufficiently random values to create session identifiers. This could allow an unauthenticated remote attacker to brute force a session identifier and gain read access to limited information from the web server without authorization.

CWE CWE-334
Vendor siemens
Product siprotec 5 6md84 (cp300)
Ecosystems
Industries
IndustrialManufacturing
Published May 12, 2026
Last Updated May 13, 2026
Stay Ahead of the Next One

Get instant alerts for siemens siprotec 5 6md84 (cp300)

Be the first to know when new medium vulnerabilities affecting siemens siprotec 5 6md84 (cp300) are published โ€” delivered to Slack, Telegram or Discord.

Get Free Alerts โ†’ Free ยท No credit card ยท 60 sec setup

CVSS v3 Breakdown

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality
Integrity
Availability

Affected Versions

Siemens / SIPROTEC 5 6MD84 (CP300)
0 < V11.0
Siemens / SIPROTEC 5 6MD85 (CP200)
All versions affected
Siemens / SIPROTEC 5 6MD85 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 6MD86 (CP200)
All versions affected
Siemens / SIPROTEC 5 6MD86 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 6MD89 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 6MU85 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 7KE85 (CP200)
All versions affected
Siemens / SIPROTEC 5 7KE85 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 7SA82 (CP100)
V7.80 < *
Siemens / SIPROTEC 5 7SA82 (CP150)
0 < V11.0
Siemens / SIPROTEC 5 7SA84 (CP200)
All versions affected
Siemens / SIPROTEC 5 7SA86 (CP200)
All versions affected
Siemens / SIPROTEC 5 7SA86 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 7SA87 (CP200)
All versions affected
Siemens / SIPROTEC 5 7SA87 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 7SD82 (CP100)
V7.80 < *
Siemens / SIPROTEC 5 7SD82 (CP150)
0 < V11.0
Siemens / SIPROTEC 5 7SD84 (CP200)
All versions affected
Siemens / SIPROTEC 5 7SD86 (CP200)
All versions affected
Siemens / SIPROTEC 5 7SD86 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 7SD87 (CP200)
All versions affected
Siemens / SIPROTEC 5 7SD87 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 7SJ81 (CP100)
V7.80 < *
Siemens / SIPROTEC 5 7SJ81 (CP150)
0 < V11.0
Siemens / SIPROTEC 5 7SJ82 (CP100)
V7.80 < *
Siemens / SIPROTEC 5 7SJ82 (CP150)
0 < V11.0
Siemens / SIPROTEC 5 7SJ85 (CP200)
All versions affected
Siemens / SIPROTEC 5 7SJ85 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 7SJ86 (CP200)
All versions affected
Siemens / SIPROTEC 5 7SJ86 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 7SK82 (CP100)
V7.80 < *
Siemens / SIPROTEC 5 7SK82 (CP150)
0 < V11.0
Siemens / SIPROTEC 5 7SK85 (CP200)
All versions affected
Siemens / SIPROTEC 5 7SK85 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 7SL82 (CP100)
V7.80 < *
Siemens / SIPROTEC 5 7SL82 (CP150)
0 < V11.0
Siemens / SIPROTEC 5 7SL86 (CP200)
All versions affected
Siemens / SIPROTEC 5 7SL86 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 7SL87 (CP200)
All versions affected
Siemens / SIPROTEC 5 7SL87 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 7SS85 (CP200)
All versions affected
Siemens / SIPROTEC 5 7SS85 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 7ST85 (CP200)
All versions affected
Siemens / SIPROTEC 5 7ST85 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 7ST86 (CP300)
0 < V11.0
Siemens / SIPROTEC 5 7SX82 (CP150)
0 < V11.0
Siemens / SIPROTEC 5 7SX85 (CP300)
0 < V11.0
Siemens / SIPROTEC 5 7SY82 (CP150)
0 < V11.0
Siemens / SIPROTEC 5 7UM85 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 7UT82 (CP100)
V7.80 < *
Siemens / SIPROTEC 5 7UT82 (CP150)
0 < V11.0
Siemens / SIPROTEC 5 7UT85 (CP200)
All versions affected
Siemens / SIPROTEC 5 7UT85 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 7UT86 (CP200)
All versions affected
Siemens / SIPROTEC 5 7UT86 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 7UT87 (CP200)
All versions affected
Siemens / SIPROTEC 5 7UT87 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 7VE85 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 7VK87 (CP200)
All versions affected
Siemens / SIPROTEC 5 7VK87 (CP300)
V7.80 < V11.0
Siemens / SIPROTEC 5 7VU85 (CP300)
0 < V11.0
Siemens / SIPROTEC 5 Compact 7SX800 (CP050)
0 < V11.0

References

NVD โ†— CVE.org โ†— EPSS Data โ†—
cert-portal.siemens.com: https://cert-portal.siemens.com/productcert/html/ssa-786884.html