๐Ÿ” CVE Alert

CVE-2023-39468

HIGH 7.2

Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability

CVSS Score
7.2
EPSS Score
0.0%
EPSS Percentile
0th

Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is required to exploit this vulnerability. The specific flaw exists within the handling of DbasSectorFileToExecuteOnReset parameter. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20799.

CWE CWE-749
Vendor triangle microworks
Product scada data gateway
Published May 3, 2024
Last Updated Aug 2, 2024
Stay Ahead of the Next One

Get instant alerts for triangle microworks scada data gateway

Be the first to know when new high vulnerabilities affecting triangle microworks scada data gateway are published โ€” delivered to Slack, Telegram or Discord.

Get Free Alerts โ†’ Free ยท No credit card ยท 60 sec setup

CVSS v3 Breakdown

CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Affected Versions

Triangle MicroWorks / SCADA Data Gateway
5.1.3.20324

References

NVD โ†— CVE.org โ†— EPSS Data โ†—
zerodayinitiative.com: https://www.zerodayinitiative.com/advisories/ZDI-23-1036/ trianglemicroworks.com: https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new